1.Inch touch screen , all commends in one touch
2.Easy – to –use software
3.LED- excitation and PD –detection,7 second top optical scanning
4.Outstanding and powerful data analysis functions
Share this product on social networks
1.Inch touch screen , all commends in one touch
2.Easy – to –use software
3.LED- excitation and PD –detection,7 second top optical scanning
4.Outstanding and powerful data analysis functions
Model |
QTC966G |
QTC966 |
QTC964G |
QTC964 |
Thermal Block | ||||
Sample capacity (wells) |
96 |
|||
Reaction volume |
0-100µL |
|||
consumables |
0.2ML 96-Well Plates (unskirt): 0.2ml 8-strip tubes,0.2ml PCR single tube (Optical flat cap,clear,frosted, white tube) |
|||
Temperature range |
0˚C.100 ˚C |
|||
Heating / cooling method |
Pettier |
|||
Max heating rate |
6.1˚C/sec |
|||
Average heating rate |
4.5˚C/sec |
|||
Max cooling rate |
5.0˚C/sec |
|||
Average cooling rate |
2.8˚C/sec |
|||
Temperature accuracy |
±0.1˚C |
|||
Temperature uniformity |
±0.1˚C |
|||
Gradient Range |
1˚C -40 ˚C |
N / A |
1˚C – 40˚C |
N / A |
Gradient block |
12 row |
12 row |
||
Special temperature protocol |
Gradient PCR,Long PCR,Touch Down PCR |
Long PCR,Touch Down PCR |
Gradient PCR,Long PCR,Touch Down PCR |
Long PCR,Touch Down PCR |
Heat Lid |
||||
Temperature range |
Room temperature 110˚C |
|||
Optical System |
||||
Excitation Source |
photodiode |
|||
Detection Position |
Excitation and scan at top |
|||
Detection method |
6 channels scanning at the same time , no edge effect |
|||
Detection time |
7 seconds for 96 wells for all channels |
|||
Range of excitation / emission wavelengths (nm) |
1.465/510(FAM,SYBR Green I,SYTO9,EvaGreen) 2. 527 / 563 (HEX,VIC,TET,JOE) 3.580 / 616 (ROX,Texas Red ) 4.632 / 664 (Cy5) 5.680 / 730 (Alexa Fluor680) 6.465 / 616 (FRET) |
1.465/510(FAM,SYBR Green I,SYTO9,EvaGreen,LC Green) 2. 527 / 563 (HEX,VIC,TET,JOE) 3.580 / 616 (ROX,Texas Red ) 4.632 / 664 (Cy5 |
||
Probe |
Taqman Probe, Molecular beacons probe ,Scorpion probe .FRET |
Taqman Probe, Molecular beacons probe ,Scorpion probe |
||
multiplexing |
Up to 6 targets |
Up to 4 targets |
||
Fluorescence Linearity |
r≥0.990 |
|||
Fluorescence Dynamic Range |
Adjustable |
|||
Performance |
||||
Sample Linearity |
/r/≥0.999 |
|||
Sample repeatability |
CT value CV≤ 0.5 % |
|||
Sample Dynamics Range |
1-1010 copies |
|||
Software Functions |
||||
Data Analysis modes |
Qualitative analysis, absolute quantification, Relative. quantification, Genotyping analysis , Endpoint analysis , Melt curve analysis ,High Resolution Melting |
|||
Control modes |
1.10.4 touch screen 2.PC direct control 3. WLAN control (One PC can control max 10 units , and decice can be controlled by any PC in the WLAN |
|||
Sample Drawer |
Touch screen commend |
|||
Data Storage |
Upload and download through USB disk , 1000 result can be stored in machine |
|||
Power failure protection |
Automatically start running experiments after power supply , no need wait PC software |
|||
Customize Report |
Templates reserved, report can customized |
|||
Administration Management |
Administrator can set function limits for users |
|||
Transport Locker |
Automatically detect transport locker |
|||
Fault Management |
Fault report and analysis, solution instruction |
|||
LIS connection |
CSV , Excel ,TXT Format data output ,open port for LIS connection |
|||
Other |
||||
PC operating system |
Win7 , Win 10 |
|||
Communication Port |
1 Ethernet and 3 USB |
|||
Footprint (WxDxH) |
355mmX480mmX485mm |
|||
Weight |
30kg |
|||
Power usage |
AC100 TO 125V/200 TO 240V(50/60 Hz) |
|||
Power consumption |
900VA |
|||
Work environment |
Temperature : 10˚C~30˚C Humidity : 20%~ 85% |